| Login In | Careers | Sitemap |
 
 
 
   
     
Click here for more information on our
100th Anniversary Year (2011)
 
 
  Business Servicesl
Installation Requirements
Metering & Installation
Planning Your Service
General Service Tariff
Secondary Voltage Tariff
Large Power Tariff
Time of Use Tariff
Renewable Energy Rider
Interruptible Service Rider
  Access Your Account
  Contact Info
  Emergencies:
(246) 626-9000


Customer Service
(246) 626-4300

PBX:
(246) 626-1800

Fax:
(246) 228-1396
     
  Business Services  
 
Renewable Energy Rider
 

» Application 
» Conditions of Service 
» Interconnection 
» Monthly Renewable Energy Credit 
» Billing 
» Terms of Service
» Rules and Regulations

» Click here to download the Requirements for Grid Interconnection of Renewable Generation Systems

» Click here to download the Renewable Energy Interconnection Agreement 

» Click here to download the Renewable Energy Power Purchase Agreement

» Click here to download the Renewable Energy Interconnection Application

APPLICATION

The Renewable Energy Rider (this “Rider”) is available as a pilot programme for a period of two (2) years to customers who qualify for the Domestic Service (DS), Employee (EMP), General Service (GS), Secondary Voltage Power (SVP), Large Power (LP) and Time-of-Use (TOU) tariffs.  All of the provisions of the applicable DS, EMP, GS, SVP, LP and TOU tariffs will apply except as amended by this Rider.  This Rider is specific to customers with renewable resource generation facilities (hereinafter collectively referred to as “customer-generators” and each as a “customer-generator”) utilizing a wind turbine, solar photovoltaic or hybrid (wind/solar) power source located on the customer’s owned or rented premises.

The customer-generator shall have a capacity of not greater than 5 kilowatts (kW) for services in the DS, EMP and GS tariffs and a capacity of not greater than 50 kW for other tariffs unless otherwise approved by the Company. This Rider is available on a first-come first-serve basis up to a maximum of 200 eligible electricity services or a combined installed capacity of 1,600 kW, whichever occurs first. The Company reserves the right to limit the number of services per individual or entity.

This Rider is applicable only to the energy supplied to the Company’s electric grid by the customer-generator. All other services supplied to the customer-generator will be billed in accordance with the rates and charges under the customer’s- applicable standard tariff.  Service under this Rider is conditional on the continuance of service to the customer under one of the applicable standard tariffs.

» BACK TO TOP

 

CONDITIONS OF SERVICE

The service under this Rider will be provided to the entire premises through a single point of delivery at a single voltage in accordance with the terms of the standard tariff applicable to the customer. The customer-generator must be:

capable of providing single or three phase voltage at 50 Hz, with its rated output not exceeding 80% of the Ampere rating of the main breaker of the installation, and manufactured, installed and operated to meet the Company’s standards for interconnection as set out in the Company’s “Renewable Energy Interconnection Agreement” and the “Requirements for Grid Interconnection of Renewable Generation Systems” and all applicable Government and industry safety and performance standards.

The Company reserves the right to disconnect the electricity supply to the entire premises to which the customer-generator is connected without notice and without incurring any liability, for failure to comply with the requirements of the interconnection agreement or for other reasons relating to safety and reliability.

The Company reserves the right to disconnect the electricity supply to the entire premises to which the customer-generator is connected without notice and without incurring any liability, for failure to comply with the requirements of the interconnection agreement or for other reasons relating to safety and reliability.

Provision must be made for the measurement of energy produced by the customer-generator through a meter provided by the Company at the customer’s expense or by the customer installing equipment suitable for this purpose, subject to the Company’s prior written approval

 

» BACK TO TOP

 

INTERCONNECTION

The customer must obtain approval in writing before any customer-generator is connected to the electric grid. Customers desirous of selling electricity to the electric grid should:

  1. apply to the Company;
  2. submit a certificate of approval from the Government Electrical Engineering Department (GEED) for connection of the customer-generator to the electrical installation;
  3. demonstrate its ability to meet the Company’s safety and performance standards and interconnection requirements;
  4. enter into an interconnection agreement with the Company, stipulating the point of connection of the customer-generator to the electricity grid; and
  5. enter into a separate power purchase agreement with the Company for a contracted period of not less than one year for electricity purchased by the Company.

» BACK TO TOP

 

MONTHLY RENEWABLE ENERGY CREDIT

All kWh supplied to the grid @ 1.8 times the Fuel Clause Adjustment or 31.5 cents/kWh, whichever is greater.

The Fuel Clause Adjustment is calculated according to the Fuel Clause approved by the Fair Trading Commission and may vary from month to month.

» BACK TO TOP

 

BILLING

The Company will utilize a Net Billing with Rolling Credit and Buyback methodology for billing purposes. At the end of each billing period, if the account is in debit after the renewable energy credits have been applied, the balance due will be billed and payable. If the account is in credit, the credit will be carried forward (rolled over) to the next billing period.

If at the end of each calendar year, the customer has accumulated a renewable energy credit and would like this to be refunded rather than rolling the credit forward, the customer may request a refund of the credit from the Company.

» BACK TO TOP

 

TERMS OF SERVICE

At the end of the pilot programme the Company will review the experience it has gained from the programme and determine whether to continue to offer this Rider.  Customers will be advised accordingly. Once a determination is made the existing customers may be required to enter into revised interconnection and power purchase agreements.

» BACK TO TOP


 

RULES & REGULATIONS

Service under this schedule is subject to the orders of the Fair Trading Commission and the latest publication of the “Information and Requirements Covering Installation of Electric Services and Meters”.  In case of a difference of interpretation between any provision of this schedule and the “Information and Requirements Covering Installation of Electric Services and Meters” booklet the provision of this schedule shall be deemed to apply.  A bill calculated under this Rider is subject to change as may be approved and / or amended by the Fair Trading Commission under the provisions of applicable riders.